polyurethane micro flow meter

Date:2017-02-01 source:
  polyurethane micro flow meter  

email: porter@microflowmeter.com  Shanghai JSNMicro Flow Meter CO.,LTD was founded in 2011 by Mr Stone and it was a familycompany which has more than 30 years history. We are specialized in highquality, high accuracym high frequence , temperature and wide measuring rangeflow measuring and detecting equipment. We strictly enforce ISO9001 standard.Our main produsts are: super mirco flow meter,oval gear flow meter ,coriolismass flow meter,electromagnetic flow meter,piston flow meter,spur gear flowmeter,gear pump,gear metering pump. Our micro flow meter can replace Kracht, OVAL,SIKA and OMAGE foreign brands and so on. Our flow meters are mainly used forwater treatment, oil, food, grease industries; chemical,ink, pharmacy, petroleum,cars; glue ,  polyurethaneand electrolyte and additives and other industries.

 polyurethane micro flow meter

polyurethane micro flow meter

Withthe development of society, the state pays more and more attention to theprocess automation instrumentation industry. However, the Oval gear flow meter industryhas been in a vacancy and has been monopolized by major foreign brands such asMax, KRACHT, OVAL, etc. , People have long endured the expensive, longdelivery, the sale can not be resolved in time and so on, such as semiconductorchip cutting a set of equipment on the millions, once the instrument problems,loss unimaginable, the slayer saw these phenomena, Resolutely resigned assenior engineer in the position of Siemens, the establishment of ShanghaiJi-sheng Instruments Co., Ltd., with great concentration on research anddevelopment of gear flow meter. We have Oval gear flow meter has been awarded anumber of certificates, it is no exaggeration to say that Qishen production Ovalgear flow meter For example, many customers replace the OVAL LSF40 with ourCX-M5-AL because it costs less than half of the LSF40, but has twice the rangethan it does and has the same accuracy.

Ovalgear flow meter is a new type of volumetric flowmeter, in addition to apositive displacement flowmeter with high accuracy, the flow is not sensitiveto other advantages, there are the following advantages: Wide range, usually inthe flow meter is 10: l, and Deep flowmeter is generally 100: 1, or even 1000:1, the accuracy is still above 0.5%, suitable for high pressure flowmeasurement, the maximum pressure can reach 100Mpa, especially suitable for themeasurement of small flow, the minimum measurement limit can be 0.3ml / min ,Less affected by the viscosity characteristics of the medium, suitable for flowmeasurement under various viscosity conditions.

micro flow meter

polyurethane micro flow meter

The Ovalgear flow meter is a volumetric flow meter that consists of a flow chamber in achamber and one or several elements that are rotated by fluid flow to form aflow meter. Leakage between the rotating element and the inner wall and theselected working range The internal flow rate is negligible. The rotation ofthe element is transmitted mechanically or by other means to the indicatingdevice to indicate the volume flow of the fluid flowing through.

 polyurethane micro flow meter

polyurethane micro flow meter

Technicaldata of Gear type flow meter

Model

K-factor

Minimum  flow

Flow  range

Accuracy

G0.025

0.025ml

0.001L/Min

0.008~2L/Min

0.5%

G0.04

0.04ml

0.004L/Min

0.2~4  L/min

0.5%

G0.1

0.4ml

0.008L/Min

0.01~8L/min

0.5%

G0.2

0.245ml

0.01L/Min

0.16~16  L/min

0.5%

G0.4

0.4ml

0.01L/Min

0.16~16  L/min

0.5%

G1

1.036ml

0.02L/Min

0.4~80  L/min

0.5%


Commonfault causes, troubleshooting

a. Thegear does not rotate: The gear is jammed by debris, the gear and cavity need tobe cleaned, and the filter is cleaned or replaced.

b. Thesmall flow error is too large: The flowmeter is installed in the wrongdirection, the best position goes up and down, or there are impurities to blockthe gear and need to be cleaned.

c. Theflow error is too large: The actual use flow range is less than or far greaterthan the flowmeter range. The corresponding flowmeter must be selected.

d. Noflow sensor signal: The gear is stuck or the circuit is connected incorrectlyor the circuit is damaged. The gear and cavity must be cleaned, or the circuitmust be correctly connected or replaced.